The effect of absorbent grid preparation method on precision and accuracy of ambient nitrogen dioxide measurements using Palmes passive diffusion tubes

View/Open
Heal(2008)JEM10_1363-9_Effect_of_PDT_absorbent_preparation.doc (299.5Kb)
Date
2008
Author
Heal, Mathew R
Metadata
Show full item record
Abstract
A few studies have suggested that the precision and accuracy of measurement of NO2 by Palmes-type passive diffusion tube (PDT) are affected by the method of preparation of the triethanolamine (TEA) absorbent coating on the grids. Theses studies have been quite limited in extent and have tended to evaluate PDT accuracy as zero bias between PDT NO2 value and the exposure-averaged NO2 determined by co-located chemiluminescence analyser. This ignores the well-documented intrinsic systematic biases on PDT-derived NO2, such as within-tube chemistry and exposure-duration nitrite loss, which may lead to non-zero bias values irrespective of effects of TEA absorbent preparation method on PDT accuracy. This paper reports on a statistical analysis of a large dataset comprising 680 duplicated PDT exposures spanning 146 separate exposures periods, spread over 5 urban exposure locations and a number of years. In each exposure period, PDTs prepared by between four and six different grid preparation methods were simultaneously compared. The preparation methods used combinations of the following: acetone or water as the TEA solvent; 20% or 50% as %TEA in the solution; and application of TEA solution by dipping grids for several minutes in the solution before drying and tube assembly, or by pipetting 50 µL of solution directly onto grids already placed in the PDT cap. These represent the range of preparation procedures typically used. Accuracy was evaluated as maximised nitrite capture within an exposure. Data were analysed by General Linear Modelling including examination of interaction between different aspects of grid preparation method. PDT precision and accuracy were both significantly better, on average, when the PDT grids were prepared by dipping in TEA solution, and neither solvent or %TEA used for the dipping solution were important. Where PDT preparation by pipetting TEA solution onto grids is to be used, better performance was obtained using 20% TEA in water. A systematic positive bias in PDT measure of NO2, consistent with within-tube oxidation of NO to NO2 and independent of preparation method, was again evident in this work.
URI
http://dx.doi.org/10.1039/b811230d

http://hdl.handle.net/1842/2533
Collections
  • Chemistry publications

Library & University Collections HomeUniversity of Edinburgh Information Services Home
Privacy & Cookies | Takedown Policy | Accessibility | Contact
Privacy & Cookies
Takedown Policy
Accessibility
Contact
feed RSS Feeds

RSS Feed not available for this page

 

 

All of ERACommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsPublication TypeSponsorSupervisorsThis CollectionBy Issue DateAuthorsTitlesSubjectsPublication TypeSponsorSupervisors
LoginRegister

Library & University Collections HomeUniversity of Edinburgh Information Services Home
Privacy & Cookies | Takedown Policy | Accessibility | Contact
Privacy & Cookies
Takedown Policy
Accessibility
Contact
feed RSS Feeds

RSS Feed not available for this page