Show simple item record

dc.contributor.advisorLinne, Mark
dc.contributor.advisorPeterson, Brian
dc.contributor.authorMecker, Nils Torge
dc.date.accessioned2020-05-26T13:41:55Z
dc.date.available2020-05-26T13:41:55Z
dc.date.issued2020-07-03
dc.identifier.urihttps://hdl.handle.net/1842/37092
dc.identifier.urihttp://dx.doi.org/10.7488/era/393
dc.description.abstractIn this thesis, the use of two-beam hybrid rotational femtosecond/picosecond coherent anti-Stokes Raman spectroscopy (HR-CARS) for temperature measurements in nitrogen gas at high pressures (1-70 atm) and temperatures (300-1000 K) is demonstrated. An experimental setup for 1 kHz measurements of well-resolved frequency-domain HR-CARS spectra across all investigated pressures and temperatures was built. To achieve the required spectral pump/Stokes excitation bandwidth, a pulse shaper was used to create an almost transform limited 42 fs pump/Stokes pulse at the interaction volume, after having passed through a 28 mm fused silica window of a high pressure cell. To obtain nonresonant background free spectra at the required spectral resolution, a narrow-bandwidth, frequency-upconverted 5.5 ps probe pulse was created in a beta barium borate (BBO) crystal (Type 1) via sum frequency generation (SFG) using second harmonic bandwidth compression (SHBC). A computational code has been developed to model S-branch HR-CARS spectra and fit to experimental results to obtain best-fit temperatures. The model spectra are based on transition frequencies calculated from a non-rigid rotor approximation, taking rotational-vibrational interaction into account. Linewidths are taken from published measurements and interpolated to the required temperature. The model assumes impulsive pump/Stokes excitation and the probe pulse is modelled with chirp, as this was observed experimentally. The fitting is done through a nonlinear least-squares algorithm. Good qualitative fits, including good accuracy and precision between thermocouple measured and best-fit temperatures over all the explored pressure and temperature regimes are shown. Across all experimental spectra, the average percentage temperature difference between best-fit and thermocouple measured temperatures (as a percentage of the thermocouple measurement), is -0.3% with a standard deviation of 7.1%. Overall, accurate nitrogen thermometry is demonstrated, showing the suitability of HR-CARS for characterising high pressure and temperature environments.en
dc.language.isoenen
dc.publisherThe University of Edinburghen
dc.relation.hasversionT. L. Courtney, N. T. Mecker, B. D. Patterson, M. Linne & C. J. Kliewer, "Generation of narrowband pulses from chirped broadband pulse frequency mixing", Opt. Lett. 44, 835-838 (2019).en
dc.relation.hasversionT. L. Courtney, N. T. Mecker, B. D. Patterson, M. Linne & C. J. Kliewer, “Hybrid femtosecond/picosecond pure rotational anti-Stokes Raman spectroscopy of nitrogen at high pressures (1-70 atm) and temperatures (300-1000 K)”, Appl. Phys. Lett. 114, 101107 (2019).en
dc.relation.hasversionN. T. Mecker, T. L. Courtney, B. D. Patterson, D. Escofet-Martín, B. Peterson, C. J. Kliewer & M. Linne,“Optimizing hybrid rotational femtosecond/picosecond coherent anti-Stokes Raman spectroscopy in nitrogen at high pressures and temperatures”, J. Opt. Soc. Am. B 37, 1035–1046 (2020).en
dc.subjectgas-phase reactionsen
dc.subjectcoherent anti-Stokes Raman spectroscopyen
dc.subjectCARSen
dc.subjectHR-CARSen
dc.subjecthybrid rotational femtosecond/picosecond CARSen
dc.subjecthigh pressureen
dc.titleHybrid rotational femtosecond/picosecond coherent anti-Stokes Raman spectroscopy of nitrogen at high pressures and temperaturesen
dc.typeThesis or Dissertationen
dc.type.qualificationlevelDoctoralen
dc.type.qualificationnamePhD Doctor of Philosophyen


Files in this item

This item appears in the following Collection(s)

Show simple item record