Show simple item record

dc.contributor.authorGales, Johnen
dc.contributor.authorBisby, Lukeen
dc.contributor.authorGillie, Martinen
dc.date.accessioned2012-01-18T13:14:38Z
dc.date.available2012-01-18T13:14:38Z
dc.date.issued2011-09
dc.identifier.citationGales, J., Bisby, L., and Gillie, M (2011) Unbonded Post Tensioned Concrete Slabs in Fire- Part I: Experimental Response of Unbonded Tendons under Transient Localized Heating. Journal of Structural Fire Engineering. 2(3):139-153.
dc.identifier.issn2040-2317
dc.identifier.urihttp://hdl.handle.net/1842/5744
dc.descriptionPart 1 of a 2 part paperen
dc.description.abstractThe fire-safe structural design and construction of unbonded post-tensioned (UPT) flat plate concrete structures has recently come under debate in the UK, and questions are being raised regarding the response to fire of post-tensioned concrete slabs. Related to these concerns is the real world response of continuous UPT tendons inside such structures both during and after a fire, which is largely unknown and depends on many potentially important factors which are not currently accounted for in standard fire tests. Several credible concerns exist for UPT concrete structures in fire, most notably the potential for premature tendon rupture due to localized heating which may result from a number of possible causes (discussed herein). The research presented in this paper deals specifically with the time-temperature-stress-strength interdependencies of stressed UPT tendons under localized transient heating, as may be experienced by tendons in a real UPT building in a real fire. Nineteen high temperature stress relaxation tests on UPT tendons of realistic length and parabolic longitudinal profile are reported. It is shown that localized heating of UPT tendons is likely to induce premature tendon rupture during fire, even in structures which meet the prescriptive concrete cover requirements imposed by available design codes.en
dc.contributor.sponsorNatural Sciences and Engineering Research Council of Canada (NSERC)en
dc.language.isoen
dc.publisherJournal of Structural Fire Engineering, Multi Scienceen
dc.subjectPrestressing steelen
dc.subjectPost-tensioned slabsen
dc.subjectUnbonded constructionen
dc.subjectFire endurance testingen
dc.subjectSpallingen
dc.subjectConcreteen
dc.subjectConcrete coveren
dc.subjectHigh temperature creepen
dc.subjectStress relaxationen
dc.titleUnbonded Post Tensioned Concrete Slabs in Fire – Part I – Experimental Response of Unbonded Tendons under Transient Localized Heatingen
dc.typeArticleen


Files in this item

This item appears in the following Collection(s)

Show simple item record