Morphometry of human lung with physiological correlations
dc.contributor.author
McLean, Alexander
en
dc.date.accessioned
2018-01-31T11:23:02Z
dc.date.available
2018-01-31T11:23:02Z
dc.date.issued
1987
dc.description.abstract
en
dc.description.abstract
Resected lobes from patients having pre-operative pulmonary function tests
were fixed by inflation with formal saline and cut into 1cm parasagittal slices.
Randomly selected tissue, from the lateral two slices, was plastic embedded
and sections prepared for microscopic analysis.
en
dc.description.abstract
A semi-automatic image analysis system was used to quantitate bronchiolar
calibre and shape and peribronchiolar attachment number, inter-alveolar
attachment distance and the amount of macroscopic emphysema. An
automatic image analyser (IBAS2) was used to measure alveolar surface area
per-unit volume (AWUV).
en
dc.description.abstract
Measured bronchiolar calibre (minimum diameter and measured lumen area)
was not related to patient height, lung volume, pulmonary function or other
morphometric variables.
en
dc.description.abstract
AWUV, mean inter-alveolar attachment distance, theoretical lumen area and
bronchiolar shape were independent of patient size and lung volume, but were
inter-related. A combination of low AWUV and loss of attachments profoundly
affected bronchiolar shape. However, AWUV and alveolar attachment loss were
not always in proportion and demonstrated different functional effects: AWUV
affects carbon monoxide transfer factor whereas attachments affect the slope
of phase III and forced expiratory volume with bronchiolar shape affecting
closing volume.
en
dc.description.abstract
Macroscopic emphysema did not accurately reflect the extent of alveolar wall
loss as identified by AWUV and showed poor correlations with pulmonary function
tests.
en
dc.description.abstract
Computerised axial tomography (CT scan) exhibited a strong correlation with
AWUV and can be used to assess lung density in life.
en
dc.identifier.uri
http://hdl.handle.net/1842/26758
dc.publisher
The University of Edinburgh
en
dc.relation.ispartof
Annexe Thesis Digitisation Project 2017 Block 15
en
dc.relation.isreferencedby
Already catalogued
en
dc.title
Morphometry of human lung with physiological correlations
en
dc.type
Thesis or Dissertation
en
dc.type.qualificationlevel
Doctoral
en
dc.type.qualificationname
PhD Doctor of Philosophy
en
Files
Original bundle
1 - 1 of 1
- Name:
- McLeanA_1987redux.pdf
- Size:
- 40.64 MB
- Format:
- Adobe Portable Document Format
This item appears in the following Collection(s)