Scaffolds and signals: design and development of a 3D printed bioreactor and electrospun polymer scaffolds for kidney tissue engineering
dc.contributor.advisor
Callanan, Anthony
en
dc.contributor.advisor
Elfick, Alistair
en
dc.contributor.author
Burton, Todd Peter
en
dc.contributor.sponsor
Engineering and Physical Sciences Research Council (EPSRC)
en
dc.date.accessioned
2019-08-05T11:01:24Z
dc.date.available
2019-08-05T11:01:24Z
dc.date.issued
2019-07-03
dc.description.abstract
There is a pressing need for further advancement in tissue engineering of functional
organs with a view to providing a more clinically relevant model for drug development
and reduce the dependence on organ donation. Polymer based scaffolds, such as
polycaprolactone (PCL), have been highlighted as a potential avenue for tissue
engineered kidneys, but there is little investigation down this stream. The focus within
kidney tissue engineering has been on two-dimensional cell culture and decellularised
tissue. The aim of this project is to utilise electrospun scaffolds within a three-dimensional
printed bioreactor system to create an ex vivo environment, to be used as
either a conditioning tool for kidney tissue engineering scaffolds or as a model for
disease.
Electrospun polymer scaffolds can be created with a variety of fibre diameters and the
variation in morphology of tissue engineered scaffolds has been shown to affect the way
cells behave and integrate. The first study of this thesis examined the cellular response
of a kidney cell-line to scaffold architecture using novel electrospun scaffolds. Two fibre
diameters were used and three distinct scaffold architectures: random, aligned and
cryogenic. The results showed that architecture of the scaffold has a profound effect on
kidney cells; whether that is effects of fibre diameter on the cell attachment and viability
or the effect of fibre arrangement on the distribution of cells and their alignment with
fibres, overall there was a preference for a larger fibre diameter of around 4 μm.
Following this, electrospun scaffolds were investigated for their potential to host a multicell
population. Rat primary kidney cells were used, and results showed that the
scaffolds were capable of sustaining a multi-population of kidney cells, determined by
the presence of: aquaporin-1 (proximal tubules), aquaporin-2 (collecting ducts),
synaptopodin (glomerular epithelia) and von Willebrand factor (glomerular endothelia
cells). Viability of cells appeared to be unaffected by fibre diameter. Overall, the ability of
electrospun polymer scaffolds to act as conveyors for kidney cells is a promising strategy
for kidney tissue engineering and one that should be explored further; the ‘non-woven
path’ provides benefits over decellularised tissue by offering a high degree of
morphological control with a scalable fabrication process and a tuneable rate of
degradation.
Investigation continued with the development of a 3D printed bioreactor. This was a
proof of concept device aiming to represent the in vivo environment. The device was
designed to be simple to use, delivering a finely controlled shear stress to cells adhered
to the scaffold in a dual chamber system, using a modified cell culture media.
Computational fluid dynamics was used to gain a better insight into the forces
experienced by cells and a modified cell culture media was used to give a better shear
distribution across the scaffold, whilst keeping the flow chamber height large. Our
investigation demonstrated the ability of the lab scale system to sustain cell life whilst
upregulating key transmembrane (AQP-2), cytoskeletal (KRT-8, KRT-18) and tight
junction (E-CAD) proteins.
Development continued, consolidating the positive characteristics of the bioreactor
whilst providing a simplified redesign. In this second-generation bioreactor, the shear
profile delivered to each side of the scaffold was mirrored with a flow regime intended to
have a low Reynolds number, allowing for the use of two different media without mixing
by convection. The device produced a shear stress of 18 to 21 mPa over 80% of the
scaffold surface on both superior and inferior sides. The bioreactor maintained a co-culture
of endothelial (HUVEC) and epithelial (RC-124) cells, showing the distinct cell
types localised on opposite sides of the bioreactor, identified by aquaporin-2 and von
Willebrand factor. This bioreactor is a useful tool for modelling of kidney tubules, but has
applications in any area where a dual environment with a controlled shear stress is
needed. Overall, this work has expanded the breadth of kidney tissue engineering
potentially guiding new potential areas of research.
en
dc.identifier.uri
http://hdl.handle.net/1842/35967
dc.language.iso
en
dc.publisher
The University of Edinburgh
en
dc.relation.hasversion
Burton, T P. Corcoran, A. Callanan, A. The effect of electrospun polycaprolactone scaffold morphology on human kidney epithelial cells. Biomedical Materials 2017;13, 15006. doi:10.1088/1748- 605X/aa8dde
en
dc.relation.hasversion
Burton, T P. Callanan, A. A Non-Woven Path: Electrospun Polylactic Acid Scaffolds for Kidney Tissue Engineering. Tissue Engineering and Regenerative Medicine, 2018. doi:10.1007/s13770-017-0107-5
en
dc.relation.hasversion
Burton, T P. Callanan, A. 2017. A 3D Printed Bioreactor with Electrospun Scaffold as a Millifluidic Renal Tubule Model, in: 2017 TERMIS- Americas Conference & Exhibition. Tissue Engineering Part A, Charlotte, USA, 2017;23, S-146.
en
dc.relation.hasversion
Burton, T P. Callanan, A. A Conditioning Platform for Kidney Tissue Engineering using a 3D Printed Bioreactor, in: 2017 TERMISAmericas Conference & Exhibition. Tissue Engineering Part A, Charlotte, USA,2017;23, S-47. doi:10.1089/ten.tea.2017.29003.abstracts.
en
dc.relation.hasversion
Wright S. Burton T P. Callanan A. Design, Development and Verification of a Technique to Manufacture Locally Strain Variant Electrospun Scaffolds for Ligament Tissue Engineering. TISSUE Eng. PART A 2017;23, S157.
en
dc.relation.hasversion
Burton T P. Callanan A. An alternative approach: electrospun polymer scaffolds for kidney tissue Engineering. Tissue and Cell Engineering Society 17th Annual Meeting, 5th-7th July, Manchester, UK, 2017.
en
dc.relation.hasversion
Burton T P. Callanan A. The implications of electrospun scaffold morphology in kidney tissue engineering. European Cells and Materials. 2016;31(Suppl. 1):79. Tissue Engineering and Regenerative Medicine International Society European Meeting, 28th June-1st July, Uppsala, Sweden.
en
dc.relation.hasversion
Burton T P. Callanan A. A dual environment 3D printed bioreactor for kidney tissue engineering. Eur Cells Mater. 2016;31(Suppl. 1):113. Tissue Engineering and Regenerative Medicine International Society European Meeting, 28th June-1st July, Uppsala, Sweden.
en
dc.subject
kidney tissue engineering
en
dc.subject
scaffolds
en
dc.subject
biodegradable polymer scaffolds
en
dc.subject
electrospinning
en
dc.subject
bioreactor
en
dc.subject
aquaporin
en
dc.title
Scaffolds and signals: design and development of a 3D printed bioreactor and electrospun polymer scaffolds for kidney tissue engineering
en
dc.type
Thesis or Dissertation
en
dc.type.qualificationlevel
Doctoral
en
dc.type.qualificationname
PhD Doctor of Philosophy
en
Files
Original bundle
1 - 1 of 1
- Name:
- Burton2019.pdf
- Size:
- 30.89 MB
- Format:
- Adobe Portable Document Format
This item appears in the following Collection(s)

